You are here:

REF615 IEC | REF615A_E | REF615_1G | ABB Series microcomputer protection measurement and control device

ABB REF615
Feeder protection and control REF615 IEC
Compact and versatile solutions for utility and industrial power distribution systems
The REF615 is a dedicated feeder protection and control relay for the protection, control, measurement and monitoring of overhead lines and cable feeders in utility and industrial distribution systems, including radial, ring and mesh distribution networks with or without distributed generation.

https://www.gsplcdcs.com/product-category/abb/

Categories:
Tags:
Email:jllucky33@qq.com
phone:(86)17372046300

Product content

 

More products are not yet in store,
Related website links can be found:

https://www.jlplc.com/

https://www.luckyplc.com/

https://www.abbsupplier.com/
https://www.abbsupplier.com/

ABB REF615
Feeder protection and control REF615 IEC
Compact and versatile solutions for utility and industrial power distribution systems
The REF615 is a dedicated feeder protection and control relay for the protection, control, measurement and monitoring of overhead lines and cable feeders in utility and industrial distribution systems, including radial, ring and mesh distribution networks with or without distributed generation.
The REF615 is a member of ABB’s Relion ® family and part of its 615 protection and control product range.

Radius

Feeder protection
Product advantage

A wide range of protection and control functions, whether using sensors or traditional instrument transformers
Off-the-shelf standard configuration, quick and easy to set up, with customization capabilities
Withdrawable plug-in design for quick installation and testing
The large graphic display is used to display customizable SLD, which can be accessed locally or through an easy-to-use Web browser-based HMI
Wide range of life cycle services

Product function

Directional and non-directional overcurrent and ground fault protection, protection and measurement based on voltage, frequency and power
Extensive grounding fault protection portfolio with unique multi-frequency admittance protection for higher sensitivity and selectivity
Optional advanced fast short-circuit and ground fault location, arc protection and high-speed output
Support for IEC 61850 Editions 1 and 2, including HSR and PRP, GOOSE messaging, and IEC 61850-9-2 LE for reduced wiring and supervised communications
IEEE 1588 V2 enables high precision time synchronization and maximizes the benefits of substation-level Ethernet communication.

 

 

PCM600 and IED connectivity package version
• Protection and Control IED Manager PCM600 Ver. 2.4 SP1 or later
• REF615 Connectivity Package Ver. 4.0 or later
• Parameter Setting
• Firmware Update
• Disturbance Handling
• Signal Monitoring
• Lifecycle Traceability
• Signal Matrix
• Communication Management
• Configuration Wizard

 

LEDs
min 8
The LHMI includes three protection indicators above the display: Ready, Start and
Trip.
There are also 11 matrix programmable LEDs on front of the LHMI. The LEDs
can be configured with PCM600 and the operation mode can be selected with the
LHMI, WHMI or PCM600.

REF615
The LHMI keypad contains push-buttons which are used to navigate in different
views or menus. With the push-buttons you can give open or close commands to
objects in the primary circuit, for example, a circuit breaker, a contactor or a disconnector. The push-buttons are also used to acknowledge alarms, reset
indications, provide help and switch between local and remote control mode

 

Audit trail
615 series IEDs offer a large set of event logging functions. Normal process related
events can be viewed by the normal user with Event Viewer in PCM600. Critical
system and IED security related events are logged to a separate non-volatile audit
trail for the administrator.
Audit trail is a chronological record of system activities that enable the
reconstruction and examination of the sequence of events and/or changes in an
event. Past user and process events can be examined and analyzed in a consistent
method with the help of Event List and Event Viewer in PCM600. The IED stores
2048 system events to non-volatile audit trail. Additionally, 1024 process events
are stored in non-volatile event list. Both audit trail and event list work according
to the FIFO principle.
User audit trail is defined according to the selected set of requirements from IEEE
1686. The logging is based on predefined usernames or user categories. The user
audit trail events are supported in IEC 61850-8-1, PCM600, LHMI and WHMI.

 

 

 