You are here:

MVME2100 | VME processor module

EmerSON/MOTOROLA MVME2100 VME processor module
Settings:
Processor: 200 MHz MPC8240
.Cache: 16 KB/16 KB
SDRAM: 32 MB
.Flash memory: 5 MB
.Handle: Scanbe

Categories:
Tags:
Email:jllucky33@qq.com
phone:(86)17372046300

Product content

 

EmerSON/MOTOROLA MVME2100 VME processor module
Settings:
Processor: 200 MHz MPC8240
.Cache: 16 KB/16 KB
SDRAM: 32 MB
.Flash memory: 5 MB
.Handle: Scanbe

Part number: 01-W3403F-03M,84-W8403F01E,01-W3403F-03J,84-W8403F01D, MVME2101-1
The confquration of the MVME2100 processor module involves many aspects. The following are some main configuration contents:
Control unit: The VME2100 control unit is the command and control center of the entire CPU,responsible for coordinating the ordery
work of the entire computer, According to the user’s pre-programmed program,it takes out each instruction from the memory in tumm, puts
it in the instruction register lR, determines what operation should be camied out through instruction decoding (analysis,. and then sends a
microoperation control signal to the corresponding component by operating the controller 0C, according to the determined timing
Arithmetic unit: Arithmetic unit is the core of the arithmetic unit, responsible for performing various arithmetic and logic operations
Storage unit: The MViME2100 storage unit consists of the on-chip cache and register group of the CPu, which is the place where data is
temporarily stored in the CPU. lt holds data that is waiting to be processed or has already been processed.
During the configuration of the processor module, the following parameter Settings need to be considered:
MVME2100 Module test completion time: used to set the answer time of the “Module configuration test completion” signal. lf thecompletion signal is not received within the specified time, the actual hardware configuration is inconsistent with the configuration. Thetime setting unit is 100ms, and the default is 650.
Parameter transfer to module: Used to set the maximum allowed time for parameters in the CPU to be transferred to each module. Thetime setting unit is 100ms. The default value is 100, For a CPU with a PROFlBUS-DP master interface, you can use this parameter to checkthe startup status of the slave.