DPM200 | DP master station module | NTMP01
Environmental condition
Model: DPM200
Operating temperature: 30 to +60°C
Relative air humidity (operating): 5 to 95%, no condensation
Storage temperature: 40 to +85°C
Relative air humidity (storage) : 5 to 95%, with condensation
Contamination level (according to IEC 60664-1) : 2(no condensation)
Categories: other
Tags: DPM200
Email:jllucky33@qq.com
phone:(86)17372046300
Product content
DPM200 | DP master station module | NTMP01
Model: DPM200
PROFIBUS® DP master station module
PROFIBUS@ is a field bus that is widely used, especially in mechanical engineering and engineering
In the field of plant engineering, even though there are a large number of Ethernet-based fieldbuses, the number still holds
Continue to increase. A wide range of peripheral components and an active user organization will also ensure the future
Long-term availability of PROFIBUS. Bachman Electronics provides a fieldbus mode for the backplane
Block, which can be used as either a master or slave station module. SolutionCenter contains
A complete configurator, which implements engineering tools with other manufacturers through consistent standard application
The interface of.
PROFIBUS® DP interface modules (distributed peripherals) can be used as DP master and DP slave
Stations or as combined master/slave stations that provide variables to other masters in a multi-master network. course
The data can be provided to the application as a logical input/output module and therefore can be mapped through the process
Or a functional interface to access process data.
Each M1 controller supports up to three DPM200 modules
Transmission rate 9.6 Kbaud to 12 Mbaud
·8 kByte registers of the process data image
The consistency lock of the data block is configurable
Two internal Bridges of the cable loop
Electrical isolation between fieldbus and controller
PROFIBUS@DP master station module :8 kB x 16 DPM
Process image size: can be updated through SolutionCenter
Firmware: 3 for each M1 controller
The maximum number of master stations is 32 without Repeaters and 125 with Repeaters
Maximum number of slave stations :Vo
PROHBUS@ Standard: 732 bytes per slave module
Data length in DPM: 400 mA/5 VDC
Environmental condition
Operating temperature: 30 to +60°C
Relative air humidity (operating): 5 to 95%, no condensation
Storage temperature: 40 to +85°C
Relative air humidity (storage) : 5 to 95%, with condensation
Contamination level (according to IEC 60664-1) : 2(no condensation)
Reviews