JKZC-YDZK03M piezoelectric impedance analyzer
The JKZC-YDZK03M piezoelectric impedance analyzer has a frequency range of 20 Hz to 120 MHz, provides 0 045% (typical value) base accuracy over a wide impedance range, and has a built-in 40 V DC bias source. The Equivalent circuit analysis function supports 7 different multi-parameter models and helps you simulate the equivalent parameter values of components.
Technical parameter
1, measurement parameters Impedance parameters | zθ zyθ Y, Cp, Cs, Lp, Ls, Rp, Rs, D, Q, R, X, G, B, complex Z, complex y Level monitoring Vac, Iac, Vdc, Idc measurement terminal configuration Four terminal pair configuration connector type Four BNC (negative head) connectors.
2, Option 120: Using Keysight 42942A terminal adapter (7mm port) or 42941A impedance probe (SMA (negative head) port) can be converted into a single port terminal.
3. Signal source characteristic frequency range 20 Hz to 120 MHz (option 120)20 Hz to 50 MHz (option 050)20 Hz to 30 MHz (option 030)20 Hz to 20 MHz (option 020)20 Hz to 10 MHz (Option 010) Resolution 1 mHz accuracy Without use Option 1E5 7 ppm ± 1 mHz7 ppm ± 1 mHz (in the temperature range of 5 to 40°C, Typical value) Use option 1E5 1 ppm ± 1 mHz (in 5 to 40°C temperature range) Stability Use option 1E5 ±0.5 ppm (in 5 to 40°C temperature range, typical value)±0.5 ppm/ year (typical value)
Two, the main characteristics
1, 5 frequency options; 20 Hz to 10/20/30/50/120 MHz, upgradeable
2, ±0.08% (±0.045% typical value) basic impedance measurement accuracy
3. 25 m? Up to 40 M? Wide impedance measurement range (10% accuracy range)
4, measurement parameters Z yθ, R, X, G, B, L, C, D, Q, complex Z, complex Y, Vac, Iac, Vdc, Idc
5, built-in DC bias source: 0 V to ±40 V, 0 A to ±100 mA
6, accelerate the measurement speed option (option 001. Only available for 10M/20M/30M/50M options)
7, 10.4 inch color LCD touch screen can display 4 channels and 4 traces
8, data analysis function: equivalent circuit analysis, limit line test