AI835A 3BSE051306R1 | CI858K01 3BSE018135R1 | Analog input module
Product model: AI835A
Item number: 3BSE051306R1
Category Description: Analog input module
Product color: new, not new
Warranty: One year
Stock: Yes
Categories: ABB
Tags: AI835A 3BSE051306R1
Email:jllucky33@qq.com
phone:(86)17372046300
Product content
AI835A 3BSE051306R1 | CI858K01 3BSE018135R1 | Analog input module
Product model: AI835A
Item number: 3BSE051306R1
Category Description: Analog input module
Product color: new, not new
Warranty: One year
Stock: Yes
Brand: ABB
dimension
Width: 45 mm (1.77 in)
Depth: 102 mm (4.01 “), 111 mm (4.37 “) including connector
Height: 119 mm (4.7 in)
Weight: 0.22 kg (0.49 lb)
Signal specification: -30… 75 mV linear; TC types B, C, D, E, J, K, L, N, R, S, T, and U
Number of channels 8
Detailed data
Resolution: 15 bits
Input impedance > 1 MΩ
Isolation: The group is isolated from the ground
Error: Maximum 0.1%
Temperature drift: Typical value 5 ppm/°C, maximum 7 ppm/°C
Update cycle time: 280 + 80 * (number of active channels) ms at 50 Hz; 250 + 70 * (number of active channels) ms at 60 Hz
Maximum field cable length 600 meters (656 yards)
Common mode rejection ratio (CMRR), 50Hz, 60Hz 120 dB
NMR, 50 Hz, 60 Hz > 60 dB
Rated insulation voltage: 50 volts
Dielectric test voltage: 500 V AC
Power consumption 1.6W
Current consumption +5 V Modulebus: 75 MA
Current consumption +24 V Modulebus: 50 MA
The AI835/AI835A offers 8 differential input channels for thermocouple /mV measurements. Each channel can be configured with a measurement range of -30 mV to +75 mV linear, or TC types B, C, E, J, K, N, R, S, and T for AI835A as well as D, L, and U.
One of the channels (channel 8) can be configured for “cold end” (ambient) temperature measurement and thus used as channel 1. CJ channel of 7. The junction temperature can be measured either locally on the MTU screw terminal or on a connection unit far from the device.
Alternatively, the fixed junction temperature of the module can be set by the user (as a parameter), or the fixed junction temperature of the AI835A can be set from the application. When CJ temperature measurement is not required, channel 8 can be used with Ch.1. 7 Use in the same way.
Characteristics and advantages
8 differential input channels for thermocouple /mV.
Channel 8 can be designated as CJ Channel (4-wire Pt100 RTD)
Types of thermocouples with the following characteristics: B, C, E, J, K, N, R, S, and AI835A, and D, L, and U
15-bit resolution (A/D)
The input is monitored to prevent disconnection
Reviews