MOOG motion controller is a brand from Wuhan, Hubei Province, and its products usually support real-time control, which can achieve high-speed and high-precision motion control.
MOOG motion controller has the advantages of high reliability, good stability and high precision, and is widely used in machinery, electronics, aerospace and other fields. Its product types include PLC, inverter, servo system, etc., which can be customized and optimized according to different application requirements.
In addition, the MOOG D138-002-001 motion controller also has a variety of communication interfaces and protocols, which can be seamlessly connected and data interaction with the host computer and other devices. At the same time, it also supports a variety of programming languages and development environments, which is convenient for users to conduct secondary development and debugging. D138-002-001 SET and Reset Instruction (SET/RST)
(1)SET(set instruction) Its role is to set and hold the target element to be operated.
(2)RST(reset instruction) resets the target element to be operated and maintains a clear state. When the SET and RST commands are used, when X0 is normally ON, Y0 becomes ON and keeps the state. Even if the XO is disconnected, YO’s ON state remains unchanged. Only when the normal open of X1 is closed, YO becomes OFF and remains, even if the normal open of X1 is disconnected, YO is still OFF.
SET, RST instruction instructions:
1) The target components of the SET instruction are Y, M, S, and the target components of the RST instruction are Y, M, S, T, C, D, V, and Z. The RST instruction is often used to clear the contents of D, Z, and V, and also to reset the integration timer and counter.
2) For the same target component, SET and RST can be used multiple times, and the order can be arbitrary, but the last executor is effective. Differential Instruction (PLSPLF)
(1)PLS(rising edge differential instruction) generates a pulse output of a scan period at the rising edge of the input signal;
(2)PLF (Falling Edge Differential Instruction) generates a pulse output of a scan cycle at the falling edge of the input signal.
The edge of the signal is detected by the differential instruction, and the state of the YO is controlled by the set and reset commands.
PLS, PLF instruction instructions:
1) The target components of PLS and PLF instructions are Y and M;
2) When PLS is used, the target component is ON only in one scan cycle after the drive input is ON, and M0 is ON only in one scan cycle when the normally open contact of X0 is off to ON; When using PLF instructions, it is only driven by the falling edge of the input signal, otherwise the same as PLS.