You are here:

DS200SDCCG1AEC | DS200PCCAG1ACB | drive master controller

DS200SDCCG1AEC technical specification

Manufacturer ge General Electric

Series mark V

Part number ds200sdccg1aec

Drive control card

Instruction manual gei-100029

Categories:
Email:jllucky33@qq.com
phone:(86)17372046300

Product content

DS200SDCCG1AEC technical specification

Manufacturer ge General Electric

Series mark V

Part number ds200sdccg1aec

Drive control card

Instruction manual gei-100029

Product description

The GE drive control board DS200SDCCG1AEC is the main controller of the drive. The GE drive control board DS200SDCCG1AEC consists of three microprocessors and RAM and can be accessed by multiple microprocessors at the same time.

If something goes wrong, there are several tools you can use to troubleshoot the board. First, open the cabinet door and check the led indicator on the board. The GE drive control board DS200SDCCG1AEC consists of 10 leds arranged on the board. When the led flashes continuously, it means that there is no error in the operation of the board. When leds blink slowly, they indicate error codes from 1 to 399. When leds blink faster, they indicate error codes between 400 and 1023.

 

 

Test points are available on the circuit board. They are metal posts that you can detect with a tester to test the signal path. The procedure can only be performed by trained service personnel, test equipment must be approved, and it must be calibrated for the task.

Another diagnostic tool you can use is the diagnostic tool available on your drive. Diagnostic tools are accessible from the control panel and they produce a detailed description of the performance of all components in the drive. If the root of the problem is found on the board, you can fix the problem and resolve it.

Diagnostic results can be downloaded from the drive to the laptop via a serial connection.

DS200SDCCG1AEC FAQ

What hardware does the DS200SDCCG1AEC include?

The DS200SDCCG1AEC has configurable hardware that must be set up correctly for each application. The berg hardware jumpers of DS200SDCCG1AEC adopt JP nomenclature, and the jumpers of DS200SDCCG1AEC adopt WJ nomenclature. DS200SDCCG1AEC Manual Manual Table 2 in GEI-100029 lists the description of jumpers of the DS200SDCCG1AEC. Figure 3 in the manual is the layout diagram of the DS200SDCCG1AEC, showing the position of jumpers of the DS200SDCCG1AEC.

What is the difference between faults on DS200SDCCG1AEC?

The fault display on the DS200SDCCG1AEC is different. On the DS200SDCCG1AEC, some fault codes are displayed in BCD form and some fault codes are displayed in binary form. DS200SDCCG1AEC The blinking rate of faults 1 to 399 is slow, and that of faults 400 to 1023 is fast.

How to reset DS200SDCCG1AEC?

The DS200SDCCG1AEC can be reset in four different ways. Press the reset button on the DS200SDCCG1AEC to reset the DS200SDCCG1AEC. The DS200SDCCG1AEC can be restored by applying +5 to +24 VDC at the customer interface point on the STBA or NTB/3TB board. The DS200SDCCG1AEC can be reset by programming software to control the reset. The reset of DS200SDCCG1AEC is realized by the internal automatic hardware watchdog protection of DS200SDCCG1AEC.