T9803 | VDC Logic I/O Module | PLCs/Machine Control

 

Description:T9803
DIGITAL INPUT TA 16
Feature buffer, enable pin
Subcategory: VDC Logic I/O Module
Category
PLCs/Machine Control
Weight: 3.00 lbs
Protocol I2C
Frequency (Max) (MHz) 0.4
VCCA (min.) (V) 0.8
VCCA (Max.) (V) 3.6
VCCB (min.) (V) 1.65
VCCB (Max.) (V) 3.6

Categories:
Tags:
Email:jllucky33@qq.com
phone:(86)17372046300

Product content

 

Description:T9803
DIGITAL INPUT TA 16
Feature buffer, enable pin
Subcategory: VDC Logic I/O Module
Category
PLCs/Machine Control
Weight: 3.00 lbs
Protocol I2C
Frequency (Max) (MHz) 0.4
VCCA (min.) (V) 0.8
VCCA (Max.) (V) 3.6
VCCB (min.) (V) 1.65
VCCB (Max.) (V) 3.6
The power limit is random
Rated list
Operating temperature range (°C) -40 to 125

Second, functional characteristics
Input/Output functions: The T9803 VDC logical I/O module has powerful input/output functions, which can realize the detection and control of the field loop or device status.
High reliability: The use of high-quality materials and advanced manufacturing processes to ensure the reliability and stability of the module.
Easy to expand: The modular design makes the system easy to expand and upgrade, and the number of modules can be increased or reduced according to actual needs.
Multiple communication modes: supports a variety of communication protocols and interface modes, and can communicate and exchange data with a variety of devices and systems.

3. Application scenarios
T9803 VDC logic I/O module is widely used in industrial automation, process control, machine manufacturing and other fields. For example, it can be used to detect and control sensors, actuators and other equipment on the production line to achieve real-time monitoring and automatic control of the production process.

 

 

Fourth, installation and maintenance
Installation: When installing the T9803 VDC logical I/O module, follow the installation steps and precautions in the product manual. Make sure the module is properly installed in the specified slot and that the required cables and wiring are connected.
Maintenance: Check and maintain the T9803 VDC logical I/O module regularly to ensure that it works properly. If a module is faulty or abnormal, repair or replace it in time.

 

 

ICS TRIPLEX T8461
ICS TRIPLEX T8151C
ICS TRIPLEX T9310-02
ICS TRIPLEX T8403
ICS TRIPLEX T9432
ICS TRIPLEX T8191
ICS TRIPLEX T8193
ICS TRIPLEX T8300
ICS TRIPLEX T8461C
ICS TRIPLEX T8431C
ICS TRIPLEX T8312-4
ICS TRIPLEX TC-215-01-6M5
ICS TRIPLEX T8314
ICS TRIPLEX TC-201-01-6M5
ICS TRIPLEX TC-201-01-4M5
ICS TRIPLEX T8403C
ICS TRIPLEX T8403CX

You may also like

Reviews (no reviews yet)

Reviews

There are no reviews yet.

Be the first to review “T9803 | VDC Logic I/O Module | PLCs/Machine Control”

Your email address will not be published. Required fields are marked *

Post comment