2024-09-13

REF615 HBFFAFAGNCA1BNA11G IEC Feeder protection and measurement and control devices

REF615 HBFFAFAGNCA1BNA11G High sensitivity and selective ground fault protection

REF615 HBFFAFAGNCA1BNA11G IEC Feeder protection and measurement and control devices are specialized feeder protection and measurement and control devices designed to protect, control, measure and monitor public and industrial distribution systems. The REF615 can be adapted to both neutral ungrounded and neutral resistance or impedance grounded networks. In addition, the REF615 can also be used for ring mesh distribution networks or radiation network protection, using the device’s advanced interstation communication capabilities. The protected grid includes multiple feeds and distributed generation.

The REF615 HBFFAFAGNCA1BNA11G IEC Feeder protection and measurement unit is available in 12 standard configurations for common feeder protection and measurement applications. The REF615 features support for the substation IEC61850 communication standard, Parallel Redundancy Protocol (PRP), and High Availability Seamless Redundancy Protocol (HSR), where the IEC61850 communication standard includes IEC 61850-9-2 LE. The relay also supports DNP3, IEC 60870-5-103 and Modbus® protocols. The Profitbus DPV1 protocol is supported through the SPA-ZC 302 protocol adapter.

The REF615 IEC feeder protection and measurement and control unit is a member of the 615 product family in ABB’s Relion® product family.

 

Major advantage

Protection, control, monitoring and management integrated in a single relay protection unit provides a compact and versatile solution for public and industrial distribution systems
With a wide range of protection and control functions, it can be used with sensors or traditional CT, PT
With pre-configured standard configurations, it can be combined faster and easier to meet the different application needs of users
Pluggable design for quick installation and testing
Large LCD screen with single line chart display, accessible locally or through an HMI that is easy to connect and browse
Thoughtful product life cycle service

Major advantage

Directional overcurrent, no directional overcurrent, ground protection, voltage, frequency and power quality protection and measurement functions
Multi-frequency admittance ground protection combination with high sensitivity and selectivity
Optional advanced and fast short-circuit and ground fault location
IEC61850 1st and 2nd editions are supported, including redundant HSR and PRP, GOOSE and IEC61850-9-2
Support IEEE 1588 v2 high precision time protocol
Supports Modbus, DNP3, and IEC 60870-5-103 communication protocols