Diaphragm press, also known as diaphragm press, plays an important role in sewage treatment in various industries. A certain number of diaphragm plates are arranged in a tight line under mechanical action to form a filter chamber. After the slurry is transported to the filter chamber by the feed pump, when the solid in the slurry forms a cake, air is passed into the diaphragm, and the expanded diaphragm will produce pressure on the filter cake, so as to carry out a secondary press and reduce the filter cake moisture content. After the dehydration is completed, the mechanical compression force of the filter plate is relieved.

 

A complete hydraulic system consists of five parts: power assembly, executive assembly, control assembly, auxiliary assembly (accessories) and hydraulic oil. We usually refer to the hydraulic system refers to the hydraulic transmission system. The hydraulic system we usually refer to refers to the hydraulic transmission system. Today, Bebon Environmental filter press manufacturers share some common problems and troubleshooting methods in the use of diaphragm filter press hydraulic system.

Diaphragm filter press common problems, causes and troubleshooting methods

When there is insufficient or no pressure in the hydraulic system, it is usually due to the following reasons:

1, hydraulic pump: reverse, need to change the direction. If the amount of oil is insufficient, you need to replenish the oil. If the parts are severely worn, the clearance will be serious, and the seal of the pipe joint will not be tight, resulting in oil leakage. At this point, it is necessary to replace or repair the parts and tighten the pipe joints.

2, safety valve: spring deformation or damage, need to be replaced. If the poppet valve and seat do not match closely, they must be replaced or adjusted. The slide valve is fixed in the open position and does not generate pressure, so it must be grounded for flexible movement.

3, if there is oil leakage in the filter press system, it must be repaired and sealed.

4. If the pressure gauge is damaged and there is no pressure ring, the filter press must be replaced immediately for parts replacement.

5, if the oil temperature is too high and the viscosity is too low, please check the specific heating reasons and take appropriate measures.